BCSP-T series manual and semi-automatic arc edge transmittance spectrum analyzer
BCSP-T series manual and semi-automatic arc edge transmittance spectrum analyzers are specially designed for the transmittance detection of small holes in mobile phone cover plates. They can measure the transmittance of various spherical and aspheric products (including planar optical samples) in the wavelength range of 380 to 1100 at high speed and with high precision. They are very suitable for the detection of small holes in the arc edge of mobile phone cover plates and other tiny optical components.
E-mail:bc@bcoptical.com
Telephone:0757-82666469
Product Description
Manual and semi-automatic model instrument introduction:
BCSP-T series manual and semi-automatic arc edge transmittance spectrum analyzers are specially designed for the transmittance detection of small holes in mobile phone cover plates. They can measure the transmittance of various spherical and aspheric products (including planar optical samples) in the wavelength range of 380 to 1100 at high speed and with high precision. They are very suitable for the detection of small holes in the arc edge of mobile phone cover plates and other tiny optical components.
BCSP-T series manual and semi-automatic arc edge transmittance spectrum analyzers are specially designed for the transmittance detection of small holes in mobile phone cover plates. They can measure the transmittance of various spherical and aspheric products (including planar optical samples) in the wavelength range of 380 to 1100 at high speed and with high precision. They are very suitable for the detection of small holes in the arc edge of mobile phone cover plates and other tiny optical components.
instrument measurement principle description:
◆ The inspection light source forms parallel light through the collimated light path, and the parallel light beam penetrates the tested sample through the focusing objective lens to reach the integrating sphere. The spectrometer collects the original data, and the special software calculates the transmission spectrum data of the sample and judges whether the product is qualified.
◆ The digital camera collects images on the surface of the sample to be measured in real time to determine whether the actual measured position is the required position, and if there is an offset, it is convenient to correct it.
◆ The inspection light source forms parallel light through the collimated light path, and the parallel light beam penetrates the tested sample through the focusing objective lens to reach the integrating sphere. The spectrometer collects the original data, and the special software calculates the transmission spectrum data of the sample and judges whether the product is qualified.
◆ The digital camera collects images on the surface of the sample to be measured in real time to determine whether the actual measured position is the required position, and if there is an offset, it is convenient to correct it.
Product features:
1. Determination of sample transmittance
The light transmittance can be measured in the wavelength range of 380 to 1100nm, especially suitable for the light transmittance measurement of mobile phone cover plates.
2. With the new design of the focus function
The self-developed focusing device can adjust the relative distance between the stage and the optical path system according to the relative difference between the real-time data of the optical path system and the sample data.
3. High speed
Due to the use of MAYP2000PRO high-performance detectors produced by the United States Ocean Optics, rapid and highly reproducible measurements can be carried out within 1 second.
4. High precision
The newly designed optical path system can ensure that the inspection light can be completely received by the detector after penetrating the sample when measuring the arc edge sample, thus improving the detection accuracy.
5. Can determine the light transmittance of small areas
Two fast-switching probes are used to measure the light transmittance of small objects of 0.3mm.
6. Measurement area visualization
The measurement area can realize visual positioning. For example, when measuring the light transmittance of the small hole on the cover plate of the mobile phone, turning on the visual function can effectively avoid the error caused by inaccurate positioning.
1. Determination of sample transmittance
The light transmittance can be measured in the wavelength range of 380 to 1100nm, especially suitable for the light transmittance measurement of mobile phone cover plates.
2. With the new design of the focus function
The self-developed focusing device can adjust the relative distance between the stage and the optical path system according to the relative difference between the real-time data of the optical path system and the sample data.
3. High speed
Due to the use of MAYP2000PRO high-performance detectors produced by the United States Ocean Optics, rapid and highly reproducible measurements can be carried out within 1 second.
4. High precision
The newly designed optical path system can ensure that the inspection light can be completely received by the detector after penetrating the sample when measuring the arc edge sample, thus improving the detection accuracy.
5. Can determine the light transmittance of small areas
Two fast-switching probes are used to measure the light transmittance of small objects of 0.3mm.
6. Measurement area visualization
The measurement area can realize visual positioning. For example, when measuring the light transmittance of the small hole on the cover plate of the mobile phone, turning on the visual function can effectively avoid the error caused by inaccurate positioning.
Automatic model instrument introduction:
BCSP-FT large-size full-automatic transmittance spectrum analyzer is a full-automatic detection equipment for measuring the transmittance of multiple IR holes. Its structure is suitable for automatic detection of large screens and can realize automatic measurement of 8-inch to 12-inch large screens. The user can automatically measure the IR holes of all cover plates by placing a stack of trays. The machine can realize full-automatic feeding, blanking, detection and OK/NG judgment without the need for operators to feed and blanking each piece. Even NG pieces will be placed back into the empty tray.
BCSP-FT large-size full-automatic transmittance spectrum analyzer is a full-automatic detection equipment for measuring the transmittance of multiple IR holes. Its structure is suitable for automatic detection of large screens and can realize automatic measurement of 8-inch to 12-inch large screens. The user can automatically measure the IR holes of all cover plates by placing a stack of trays. The machine can realize full-automatic feeding, blanking, detection and OK/NG judgment without the need for operators to feed and blanking each piece. Even NG pieces will be placed back into the empty tray.
Product features:
1. Fully automatic loading and unloading
In the loading area and the blanking area, 40 discs can be stacked respectively.
2. Visual alignment accuracy is higher
Through the camera vision alignment, the detection accuracy is higher.
3. One-time measurement of porous
For samples with multiple holes, the visual one-time positioning measures the multi-holes by the robot displacement once.
4. OK/NG sample material frame automatic recovery
When OK products are measured, the sample is returned to the tray. When NG products are measured, the tray is retracted to NG empty tray, and the tray is automatically loaded and unloaded for recovery.
5. Four-axis SCARA manipulator loading and unloading
Through the four-axis SCARA manipulator to grasp, shift, and discharge, the stability is higher and the efficiency is faster.
6. IR measurement hole position is flexible
Whether the IR hole is on the long side or the short side, it can be measured.
1. Fully automatic loading and unloading
In the loading area and the blanking area, 40 discs can be stacked respectively.
2. Visual alignment accuracy is higher
Through the camera vision alignment, the detection accuracy is higher.
3. One-time measurement of porous
For samples with multiple holes, the visual one-time positioning measures the multi-holes by the robot displacement once.
4. OK/NG sample material frame automatic recovery
When OK products are measured, the sample is returned to the tray. When NG products are measured, the tray is retracted to NG empty tray, and the tray is automatically loaded and unloaded for recovery.
5. Four-axis SCARA manipulator loading and unloading
Through the four-axis SCARA manipulator to grasp, shift, and discharge, the stability is higher and the efficiency is faster.
6. IR measurement hole position is flexible
Whether the IR hole is on the long side or the short side, it can be measured.